I-Electrode Yokushisela Yensimbi Ephansi Ye-Alloy
J607CrNiMo
I-GB/T E6015-G
I-AWS E9015-G
Incazelo: I-J607CrNiMo iyi-electrode yensimbi e-alloy ephansi ene-hydrogen sodium ephansi. Sebenzisa i-DCEP (i-electrode yamanje eqondile), futhi ingashintshwa kuzo zonke izikhundla ngokusebenza okufushane kwe-arc. Induku yokushisela inobubanzi obukhulu bokungena, ukuchitheka okuncane kanye nokusebenza okuhle kokusebenza. Insimbi efakiwe inokuqina okuhle, ukuqina okuphansi kokushisa kanye nokumelana nokuqhekeka.
Ukusetshenziswa: Isetshenziselwa ukushisela amapayipi okuhambisa amanzi angaphansi kuka-350 °C eziteshini zikagesi kanye nezinsimbi zemikhumbi yokucindezela zamazinga ahambisanayo okuqina. Ihambisana kahle nensimbi yasekhaya ye-WB36CN1 (HD15Ni1MnMoNbCu), futhi ifanelekela nokushisela insimbi ye-WB3 (15NiCuMoNb5).
Ukwakheka kwamakhemikhali kwensimbi eshidiwe (%):
| C | Mn | Si | Cr | Ni | Mo | S | P |
| ≤0.10 | 1.00 ~ 1.60 | ≤0.50 | 0.14 ~ 0.35 | 0.60 ~ 1.20 | 0.15 ~ 0.50 | ≤0.015 | ≤0.015 |
Izakhiwo zemishini zensimbi yokushisela:
| Into yokuhlola | Amandla okudonsa I-Mpa | Amandla okukhiqiza I-Mpa | Ukwelulwa % | Inani lomthelela (J) -30℃ |
| Kuqinisekisiwe | 620 ~ 720 | ≥500 | ≥20 | ≥47 |
Okuqukethwe kwe-hydrogen okusabalala kwensimbi egciniwe: ≤5.0mL/100g (indlela ye-mercury noma i-gas chromatography)
Ukuhlolwa kwe-X-ray: Ibanga lokuqala
I-current enconyiwe:
| (mm) Ububanzi benduku | 3.2 | 4.0 | 5.0 |
| (A) Ukushisela Kwamanje | 100 ~ 140 | 140 ~ 18 | 190 ~ 230 |
Isaziso:
1. I-electrode kumele ibhakwe ihora eli-1 cishe ku-350℃ ngaphambi kokusebenza kokushisela;
2. Kubalulekile ukuhlanza izikali zikawoyela, amanzi kanye nokungcola okugqwalile ezingxenyeni zokushisela ngaphambi kokushisela.